- 将电池模块从ADC直接采样改为使用sensor子系统,通过battery_sense传感器获取电压 - 将模式切换模块从ADC采样改为使用mode_sense传感器获取模式电压 - 移除GPIO控制的电池使能脚,改用传感器的PM管理机制 - 更新DTS配置,移除大量设备状态设置,添加boot-mode保留内存支持 perf(pm): 调整分区大小以支持单应用引导模式 - 将mcuboot分区从0xc000扩大到0x100,为单应用模式提供更大空间 - 相应调整app分区地址布局,确保内存分配合理 - 移除secondary镜像相关配置,优化flash使用 refactor(boot): 添加MCUBOOT单应用模式配置 - 在sysbuild中启用单应用模式支持 - 为引导加载程序添加保留内存和启动模式配置 - 配置CDC ACM串口用于引导模式通信
48 lines
1.1 KiB
Plaintext
48 lines
1.1 KiB
Plaintext
#include <zephyr/dt-bindings/gpio/gpio.h>
|
|
|
|
/ {
|
|
chosen {
|
|
zephyr,boot-mode = &boot_mode0;
|
|
};
|
|
|
|
hid_dev_0: hid_dev_0 {
|
|
compatible = "zephyr,hid-device";
|
|
label = "HID_BOOT";
|
|
protocol-code = "keyboard";
|
|
in-report-size = <8>;
|
|
in-polling-period-us = <1000>;
|
|
out-report-size = <8>;
|
|
out-polling-period-us = <1000>;
|
|
};
|
|
|
|
hid_dev_1: hid_dev_1 {
|
|
compatible = "zephyr,hid-device";
|
|
label = "HID_NKRO";
|
|
protocol-code = "none";
|
|
in-report-size = <31>;
|
|
in-polling-period-us = <1000>;
|
|
out-report-size = <31>;
|
|
out-polling-period-us = <1000>;
|
|
};
|
|
|
|
raw_hid: hid_dev_2 {
|
|
compatible = "zephyr,hid-device";
|
|
label = "HID_RAW";
|
|
protocol-code = "none";
|
|
in-report-size = <64>;
|
|
in-polling-period-us = <1000>;
|
|
out-report-size = <64>;
|
|
out-polling-period-us = <1000>;
|
|
};
|
|
};
|
|
|
|
&gpregret1 {
|
|
status = "okay";
|
|
|
|
boot_mode0: boot_mode@0 {
|
|
compatible = "zephyr,retention";
|
|
status = "okay";
|
|
reg = <0x0 0x1>;
|
|
};
|
|
};
|